Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Rev Col Bras Cir ; 47: e20202481, 2020.
Artigo em Inglês, Português | MEDLINE | ID: mdl-32965301

RESUMO

OBJECTIVE: Endovascular treatment for femoropopliteal arterial disease has made revascularization procedures less invasive, but the self-expanding stents used can suffer great wear in arteries with extreme mobility. To evaluate the prevalence of fractures in stents implanted in the femoropopliteal segment, to identify predisposing factors and consequences on arterial patency. METHOD: between March and June 2019, thirty patients previously operated for femoropopliteal obstruction underwent stent X-rays in anteroposterior and lateral views to detect fractures and Doppler to analyze arterial patency. RESULTS: we observed 12 cases with fractures (33.3%): 1 type I (2.8%), 3 type II (8.3%), 5 type III (13.9%), 3 type IV (8.3%) and no type V. According to the TASC II we had 1 in group B (8.3%), 6 in group C (50%) and 5 in group D (41.6%) p <0.004. The number of stents per limb was 3.1 (± 1.3) in cases of fracture versus 2.3 (± 1.3) in cases without fracture (p = 0.08). The extension was 274.17mm (± 100.94) in cases of fracture and 230.83mm (± 135.44) in cases without fracture (p = 0.29). On Doppler we had: 17 patients (47.2%) without stenosis, 9 patients (25%) with stenosis> 50% and 10 patients (27.8%) with occlusion (p = 0.37). There was no correlation between fracture and arterial obstruction (p = 0.33). CONCLUSION: stent fractures are a frequent finding in the femoropopliteal area (33.3%), being more prevalent in cases of more advanced disease (C and D). There was no association between the finding of fracture and arterial obstruction.


Assuntos
Procedimentos Endovasculares/métodos , Doença Arterial Periférica , Doenças Vasculares Periféricas/terapia , Artéria Poplítea , Falha de Prótese , Stents , Ultrassonografia Doppler em Cores/métodos , Humanos , Perna (Membro)/irrigação sanguínea , Doenças Vasculares Periféricas/diagnóstico por imagem , Prevalência , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Grau de Desobstrução Vascular
2.
Rev. Col. Bras. Cir ; 47: e20202481, 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1136536

RESUMO

ABSTRACT Endovascular treatment for femoropopliteal arterial disease has made revascularization procedures less invasive, but the self-expanding stents used can suffer great wear in arteries with extreme mobility. Objective: to evaluate the prevalence of fractures in stents implanted in the femoropopliteal segment, to identify predisposing factors and consequences on arterial patency. Method: between March and June 2019, thirty patients previously operated for femoropopliteal obstruction underwent stent X-rays in anteroposterior and lateral views to detect fractures and Doppler to analyze arterial patency. Results: we observed 12 cases with fractures (33.3%): 1 type I (2.8%), 3 type II (8.3%), 5 type III (13.9%), 3 type IV (8.3%) and no type V. According to the TASC II we had 1 in group B (8.3%), 6 in group C (50%) and 5 in group D (41.6%) p <0.004. The number of stents per limb was 3.1 (± 1.3) in cases of fracture versus 2.3 (± 1.3) in cases without fracture (p = 0.08). The extension was 274.17mm (± 100.94) in cases of fracture and 230.83mm (± 135.44) in cases without fracture (p = 0.29). On Doppler we had: 17 patients (47.2%) without stenosis, 9 patients (25%) with stenosis> 50% and 10 patients (27.8%) with occlusion (p = 0.37). There was no correlation between fracture and arterial obstruction (p = 0.33). Conclusion: stent fractures are a frequent finding in the femoropopliteal area (33.3%), being more prevalent in cases of more advanced disease (C and D). There was no association between the finding of fracture and arterial obstruction.


RESUMO Os tratamentos endovasculares para a doença arterial obstrutiva fêmoro-poplítea tornaram os procedimentos de revascularização menos invasivos, porém os stents metálicos autoexpansíveis utilizados podem sofrer grande desgaste em artérias com extrema mobilidade. Objetivo: avaliar a prevalência de fraturas em stents implantados no segmento fêmoro-poplíteo, identificar fatores predisponentes e possíveis consequências sobre a patência arterial. Métodos: entre março a junho de 2019, trinta pacientes previamente operados por obstrução fêmoro-poplítea realizaram RX dos stents em incidências ântero-posterior e perfil para detectar fraturas e eco Doppler para analisar a patência arterial. Resultados: observamos 12 casos com fraturas (33,3%): 1 do tipo I (2,8%), 3 do tipo II (8,3%), 5 do tipo III (13,9%), 3 do tipo IV (8,3%) e nenhuma tipo V. Segundo a classificação TASC II, tivemos 1 no grupo B (8,3%), 6 no grupo C (50%) e 5 no grupo D (41,6%) p<0,004. O número de stents por membro foi de 3,1 (±1,3) nos casos de fratura contra 2,3 (±1,3) nos casos sem fratura (p = 0,08). A extensão tratada foi 274,17mm (±100,94) nos casos de fratura e 230,83mm (±135,44) nos casos sem fratura (p=0,29). No Doppler tivemos: 17 pacientes (47,2%) sem estenose, 9 pacientes (25%) com estenose>50% e 10 pacientes (27,8%) com oclusão (p=0,37). Não houve correlação entre fratura e obstrução arterial (p=0,33). Conclusão: as fraturas de stents são um achado frequente no setor fêmoro-poplíteo (33,3%) sendo mais prevalentes nos casos de doença mais avançada TASC II C e D. Não houve associação entre o achado de fratura e obstrução arterial.


Assuntos
Humanos , Artéria Poplítea , Falha de Prótese , Stents , Doenças Vasculares Periféricas/terapia , Ultrassonografia Doppler em Cores/métodos , Doença Arterial Periférica , Procedimentos Endovasculares/métodos , Desenho de Prótese , Grau de Desobstrução Vascular , Prevalência , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Doenças Vasculares Periféricas/diagnóstico por imagem , Perna (Membro)/irrigação sanguínea
3.
Rev. Col. Bras. Cir ; 40(5): 386-391, set.-out. 2013. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-698075

RESUMO

OBJETIVO: avaliar a utilização de uma nova partícula de polivinil álcool e polivinil acetato (PVA-PVAc) esférica, para embolização das artérias uterinas, em pacientes portadoras de mioma, com indicação cirúrgica. MÉTODOS: doze pacientes foram submetidas à embolização de miomas uterinos com partículas de PVA-PVAc. Três a nove meses depois, realizou-se uma laparotomia com miomectomia. Analisaram-se os seguintes parâmetros: volume do útero e do maior mioma; concentrações do hormônio folículo estimulante e de hemoglobina; sangramento menstrual (número de dias e de absorventes utilizados), sinais e sintomas antes do tratamento, após a embolização e após a miomectomia. RESULTADOS: a média de idade foi 37 anos e a média do volume uterino, previamente ao tratamento, de 939,3cc. Três anos após a embolização, observou-se diminuição do volume uterino (p=0,0005). Houve melhora na concentração de hemoglobina (p= 0,0004), com elevação após a embolização, sem variação subsequente à miomectomia. Não ocorreu variação significante do hormônio folículo estimulante, (p=0,17). Não foi constatado nenhum caso de falência ovariana, mas uma das pacientes apresentou atrofia de endométrio. Duas pacientes engravidaram, com bons indicadores obstétricos. Quanto aos sinais e sintomas, houve melhora após a embolização, que se manteve após a miomectomia. CONCLUSÃO: a embolização arterial com partículas de PVA-PVAc esférico mostrou-se promissora no preparo para uma intervenção cirúrgica com retirada dos miomas, pois, associou-se à redução do volume uterino, à diminuição do sangramento operatório e tornou possível a utilização de incisões menores, aumentando a chance de preservação do útero.


OBJECTIVE: To evaluate the use of a new spherical particle of polyvinyl alcohol and polyvinyl acetate (PVA-PVAc) for uterine artery embolization in patients with myoma with surgical indication. METHODS: twelve patients underwent uterine myoma embolization with PVA-PVAc particles. Three to nine months later, they were submitted to laparotomy with myomectomy. We analyzed the following parameters: volume of the uterus and of the bigger myoma; concentrations of follicle stimulating hormone and hemoglobin; menstrual bleeding (number of days and used absorbents), signs and symptoms before treatment, after embolization and after myomectomy. RESULTS: The mean age was 37 years and mean uterine volume prior to treatment, 939.3 cc. Three years after embolization, there was reduction in uterine volume (p = 0.0005), increase in hemoglobin concentration after embolization (p = 0.0004), without variation after the myomectomy. There was no significant variation of the follicle stimulating hormone (p = 0.17). There was no case of ovarian failure, but one of the patients had endometrial atrophy. Two patients became pregnant, with good obstetric indicators. Signs and symptoms improved after embolization, and remained after myomectomy. CONCLUSION: Arterial embolization with spherical PVA-PVAc particles is promising in the preparation for myoma surgery, since it was associated with a reduction in uterine volume, decrease in intraoperative bleeding and made possible the use of smaller incisions, increasing the chance of preserving the uterus.


Assuntos
Adulto , Feminino , Humanos , Adulto Jovem , Leiomioma/terapia , Álcool de Polivinil , Polivinil , Embolização da Artéria Uterina , Neoplasias Uterinas/terapia , Cuidados Pré-Operatórios
4.
Rev Col Bras Cir ; 40(5): 386-91, 2013.
Artigo em Inglês, Português | MEDLINE | ID: mdl-24573587

RESUMO

OBJECTIVE: To evaluate the use of a new spherical particle of polyvinyl alcohol and polyvinyl acetate (PVA-PVAc) for uterine artery embolization in patients with myoma with surgical indication. METHODS: twelve patients underwent uterine myoma embolization with PVA-PVAc particles. Three to nine months later, they were submitted to laparotomy with myomectomy. We analyzed the following parameters: volume of the uterus and of the bigger myoma; concentrations of follicle stimulating hormone and hemoglobin; menstrual bleeding (number of days and used absorbents), signs and symptoms before treatment, after embolization and after myomectomy. RESULTS: The mean age was 37 years and mean uterine volume prior to treatment, 939.3 cc. Three years after embolization, there was reduction in uterine volume (p = 0.0005), increase in hemoglobin concentration after embolization (p = 0.0004), without variation after the myomectomy. There was no significant variation of the follicle stimulating hormone (p = 0.17). There was no case of ovarian failure, but one of the patients had endometrial atrophy. Two patients became pregnant, with good obstetric indicators. Signs and symptoms improved after embolization, and remained after myomectomy. CONCLUSION: Arterial embolization with spherical PVA-PVAc particles is promising in the preparation for myoma surgery, since it was associated with a reduction in uterine volume, decrease in intraoperative bleeding and made possible the use of smaller incisions, increasing the chance of preserving the uterus.


Assuntos
Leiomioma/terapia , Álcool de Polivinil , Polivinil , Embolização da Artéria Uterina , Neoplasias Uterinas/terapia , Adulto , Feminino , Humanos , Cuidados Pré-Operatórios , Adulto Jovem
5.
Radiol. bras ; 41(4): 213-217, jul.-ago. 2008. ilus
Artigo em Inglês, Português | LILACS | ID: lil-492325

RESUMO

OBJETIVO: Este estudo tem como objetivo a avaliação pós-operatória do tratamento endovascular de aneurismas da aorta abdominal por angiotomografia com multidetectores. MATERIAIS E MÉTODOS: Foram analisadas, retrospectivamente, angiotomografias de 166 pacientes (137 homens e 29 mulheres) com idade média de 73 anos portadores de aneurisma da aorta abdominal submetidos a terapêutica endovascular, no período de junho de 2005 a agosto de 2006. Os exames foram feitos em tomógrafo multidetector de 64 canais e os parâmetros adotados foram: colimação, 0,625 mm; pitch, 0,6-1; mAs, 300-400; kV, 120. Em todos os casos foi utilizado meio de contraste iodado não-iônico (350 mg/ml) administrado por meio de bomba infusora, com fluxo de 4 ml/s a 5 ml/s e com volume variável de 70 ml a 100 ml. Os exames foram avaliados quanto à presença de complicações. RESULTADOS: Dos 166 exames realizados, 93 pacientes não apresentaram complicações e 73 apresentaram os seguintes achados: endoleak (n=37), trombose circunferencial da endoprótese (n=29), angulação (n=17), coleção no sítio de punção (n=10), migração da prótese (n=7), dissecção dos vasos de acesso (n=7) e oclusão (n=6). CONCLUSÃO: O endoleak foi a complicação mais prevalente em nosso estudo, sendo o tipo II o mais comum.


OBJECTIVE: The present study was aimed at evaluating endovascularly treated abdominal aortic aneurysms by multidetector computed tomography angiography. MATERIALS AND METHODS: Multidetector computed tomography angiography studies of 166 patients were retrospectively analyzed. The sample included 137 men and 29 women with mean age of 73 years who had undergone endovascular treatment for abdominal aortic aneurysm in the period between June 2005 and August 2006. Images were acquired in a 64-channel multidetector tomograph adopting the following parameters: 0.625 mm collimation, pitch 0.6-1, 300-400 mAs, and 120 kV. A nonionic iodinated contrast agent (350 mg/ml) was injected by infusion pump at a rate of 4 ml/s to 5 ml/s and a variable amount of 70 ml to 100 ml. The studies were evaluated for the presence of complications. RESULTS: Among the 166 cases, 93 patients did not present complications and 73 presented the following findings: endoleak (n=37), circumferential thrombosis (n =29), angulation (n=17), presence of collection at the puncture site (n=10), graft migration (n=7), dissection of access vessels (n=7) and occlusion (n=6). CONCLUSION: In summary, endoleak was the most prevalent complication in the present series, with type II endoleak being most frequently found.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico , Complicações Pós-Operatórias , Aneurisma da Aorta Abdominal/etiologia , Brasil , Avaliação de Resultado de Intervenções Terapêuticas , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
6.
Rev. Col. Bras. Cir ; 35(4): 252-258, jul.-ago. 2008. ilus, tab
Artigo em Português | LILACS | ID: lil-494172

RESUMO

OBJETIVO: Avaliar e comparar a resposta tecidual de uma endoprótese biosintetica implantada na aorta torácica descendente e veia cava inferior de suínos. MÉTODO: Foi implantada uma endoprótese auto-expansível composta de aço inoxidável, revestida por veia jugular de bovino, processada pelo método L-hydro, com auxilio de uma bainha de liberação Taheri-Leonhardt (Flórida, EUA) na aorta torácica descendente, e a veia cava infra-renal de 10 suínos. Sessenta dias após, as endopróteses foram retiradas e analisadas sob o ponto de vista macro e microscópicos. Foram observados: perviedade, grau de incorporação a parede do vaso, tipo de reação inflamatória, e local de maior resposta, tanto em relação a camada do vaso quanto ao local de contato com o anel de aço RESULTADOS: Todas as endopróteses encontravam-se pérvias, e incorporadas à parede. No setor venoso, seis apresentaram traves fibrosas em sua luz, e quatro apresentaram fibrose perivascular. No setor arterial somente uma prótese apresentou discreta estenose, sem fibrose perivascular. A reação inflamatória crônica tipo corpo estranho ocorreu em 100 por cento das peças, a camada média foi a mais acometida no setor venoso, enquanto a íntima foi mais constante na artéria, o grau de incorporação foi mais firme na veia em comparação a artéria. A reação tecidual mostrou maior tendência nas áreas em intimo contato com o anel de aço (intra-anelar), mais intensa na artéria do que na veia. CONCLUSÃO: A prótese apresentou baixa trombogenicidade em ambos os sistemas, houve maior reação tecidual e baixa biocompatibilidade no setor venoso.


BACKGROUND: To evaluate and compare the tissue response, in swine, to a biosynthetic stent-graft when implanted in both thoracic aorta and inferior vena cava. METHOD: It was used a self-expanding stainless stent, covered by segment of bovine jugular veins, processed by the method L-hydro, and delivered by Taheri-Leonhardt system (Florida, USA) . The implants were done in the descending thoracic aorta, and in the infra-renal vena cava of 10 swines. Sixty days after, the endoprosthesis were removed and analyzed under macro and microscopic view. The following parameters were analyzed: patency, incorporation to the vessel wall, type of inflammatory reaction, tissue response concerning the layer of the vessel as for the contact with the ring steel. RESULTS: All implanted stent-grafts were patent, and incorporated to the vessel wall. Six presented fibrous bars, and four presented perivascular fibrosis at the venous section. At the arterial section, only one prosthesis developed a very small stenosis, without perivascular fibrosis. We observed chronic inflammatory reaction with a foreign body granulomatous response in 100 percent of the samples, the medium layer was the more prevalent at the vein section, while the intima layer was more constant at the artery, venous incorporation was stronger than artery incorporation, and tissue response was enhanced in the inner contact between the vessel wall and the ring steel. CONCLUSION: The prosthesis in study presented low thrombogenicity in both systems. It was also present, larger tissue response and low biocompatibility at the venous system, and better biocompatibility at the arterial system.

7.
Arq Bras Cardiol ; 87(3): 321-8, 2006 Sep.
Artigo em Inglês, Português | MEDLINE | ID: mdl-17057933

RESUMO

OBJECTIVE: To test the efficiency of the direct duplex scanning parameters in the diagnosis of renal artery stenosis (RAS), and verify whether or not the cut-off points recommended by medical literature are the most appropriate means to distinguish lesion severity. METHODS: Prospective study, including 62 patients with RAS, submitted to a duplex ultrasound scan and selective arteriography. The peak systolic velocity (PSV) and the renal-aortic ratio (RAR) were measured. Statistical analysis included the ROC (receiver operating characteristic curve), unpaired students t-test, sensitivity, specificity, positive and negative predictive values and accuracy. RESULTS: The arteriography revealed RAS 0-59% in 31 arteries (24%); RAS 60-99% in 91 arteries (72%) and 5 occlusions (4%). ROC analysis demonstrated that the lesion detection efficiency of PSV and RAR were similar with areas below the curves of 0.96 and 0.95, respectively. Considering the cut-off points recommended by medical literature, PSV of 180 cm/sec presented a sensitivity of 100% and specificity of 81%, while the RAR of 3.5 presented a sensitivity of only 79%, with a specificity of 93%. These parameters were analyzed in conjunction (direct criteria) revealing a sensitivity of 79% and specificity of 97%. The optimized cut-off points were: PSV of 189 cm/sec and RAR of 2.6, demonstrating sensitivity and specificity rates of 100%, 87%, 96% and 87% respectively. CONCLUSION: The individual use of optimized peak systolic velocity (PSV) was the most efficient parameter in the detection and grading of RAS.


Assuntos
Obstrução da Artéria Renal/diagnóstico por imagem , Ultrassonografia Doppler Dupla , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia , Métodos Epidemiológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
8.
Arq. bras. cardiol ; 87(3): 321-328, set. 2006. ilus, tab, graf
Artigo em Português | LILACS | ID: lil-436194

RESUMO

OBJETIVO: Testar o desempenho dos parâmetros diretos do duplex scan no diagnóstico da estenose da artéria renal (EAR) e verificar se os pontos de corte recomendados pela literatura são os mais adequados para se discriminar a gravidade da lesão. MÉTODOS: Estudo prospectivo, incluindo 62 pacientes portadores de EAR, submetidos ao duplex scan, seguido da arteriografia seletiva. O pico de velocidade sistólico (PVS) e a relação renal-aorta (RRA) foram mensurados. A análise estatística incluiu a curva ROC (receiver operating characteristic curve), t test student não pareado a sensibilidade, especificidade, os valores preditivos positivo e negativo, e a acurácia. RESULTADOS: A arteriografia revelou EAR 0-59 por cento em 31 artérias (24 por cento); EAR 60-99 por cento em 91 artérias (72 por cento) e 5 oclusões (4 por cento). A análise de ROC mostrou que o PVS e a RRA apresentaram desempenho semelhante na detecção da lesão, cujas áreas sob as curvas foram 0,96 e 0,95, respectivamente. Considerando os pontos de corte recomendados pela literatura, o PVS de 180 cm/s apresentou sensibilidade de 100 por cento e especificidade de 81 por cento, enquanto que a RRA de 3,5 apresentou sensibilidade de somente 79 por cento, com 93 por cento de especificidade. Estes parâmetros foram analisados de forma conjugada (critério direto), revelando 79 por cento de sensibilidade e 97 por cento de especificidade. Os pontos de corte otimizados foram: PVS de 189 cm/s e RRA de 2,6, demonstrando 100 por cento, 87 por cento, 96 por cento e 87 por cento de sensibilidade e especificidade para o PVS e para a RRA, respectivamente. CONCLUSÃO: O uso isolado do PVS otimizado apresentou o melhor desempenho na detecção e na graduação da EAR.


OBJECTIVE: To test the efficiency of the direct duplex scanning parameters in the diagnosis of renal artery stenosis (RAS), and verify whether or not the cut-off points recommended by medical literature are the most appropriate means to distinguish lesion severity. METHODS: Prospective study, including 62 patients with RAS, submitted to a duplex ultrasound scan and selective arteriography. The peak systolic velocity (PSV) and the renal-aortic ratio (RAR) were measured. Statistical analysis included the ROC (receiver operating characteristic curve), unpaired studentÆs t-test, sensitivity, specificity, positive and negative predictive values and accuracy. RESULTS: The arteriography revealed RAS 0-59 percent in 31 arteries (24 percent); RAS 60-99 percent in 91 arteries (72 percent) and 5 occlusions (4 percent). ROC analysis demonstrated that the lesion detection efficiency of PSV and RAR were similar with areas below the curves of 0.96 and 0.95, respectively. Considering the cut-off points recommended by medical literature, PSV of 180 cm/sec presented a sensitivity of 100 percent and specificity of 81 percent, while the RAR of 3.5 presented a sensitivity of only 79 percent, with a specificity of 93 percent. These parameters were analyzed in conjunction (direct criteria) revealing a sensitivity of 79 percent and specificity of 97 percent. The optimized cut-off points were: PSV of 189 cm/sec and RAR of 2.6, demonstrating sensitivity and specificity rates of 100 percent, 87 percent, 96 percent and 87 percent respectively. CONCLUSION: The individual use of optimized peak systolic velocity (PSV) was the most efficient parameter in the detection and grading of RAS.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Obstrução da Artéria Renal , Ultrassonografia Doppler Dupla , Angiografia , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Curva ROC , Obstrução da Artéria Renal , Sensibilidade e Especificidade , Índice de Gravidade de Doença
9.
J. vasc. bras ; 5(2): 81-88, jun. 2006. ilus, tab
Artigo em Português | LILACS | ID: lil-446574

RESUMO

Objetivo: avaliar a resposta tissular a uma endoprótese, com cobertura biológica, implantada em veia cava inferior de suínos. Métodos: Desenvolvemos uma endoprótese auto-expansível, revestida com um segmento de jugular bovina, conservada por processo L-hydro e saturada em um stent de aço inoxidável 316L. O dispositivo introdutor utilizado foi a bainha de liberação da endoprótese aórtica Taheri-Leonhardt (Flórida, EUA). Foram implantadas endopróteses em 10 suínos, todas na veia cava infra-renal. Os animais foram submetidos à flebografia peroperatória. À necropsia, após 2 meses, cada endoprótese foi retirada em bloco e analisada macroscopicamente, visando a avaliação da perviedade, aderência aos tecidos vizinhos e incorporação à parede venosa; e, histopatologicamente, visando a resposta histológica ao enxerto. Resultados: Na análise macroscópica, todas as endopróteses encontravam-se pérvias e totalmente incorporadas à parede venosa, porém seis apresentavam trabeculações grosseiras no seu interior e quatro algum grau de fibros perivascular. Três animais desenvolveram linfocele, uma retroperitonial e as outras na parede abdominal...


Assuntos
Animais , Feminino , Cobaias , Bioprótese , Bioprótese/veterinária , Bovinos/anatomia & histologia , Bovinos/cirurgia , Histocompatibilidade/fisiologia , Histocompatibilidade/genética , Veia Cava Inferior/anatomia & histologia , Veia Cava Inferior/cirurgia , Veias Jugulares/cirurgia
10.
Rev. bras. cir ; 81(2): 85-8, mar.-abr. 1991. ilus
Artigo em Português | LILACS | ID: lil-99953

RESUMO

Os aneurismas múltiplos dos ramos viscerais da aorta abdominal constituem uma condiçäo patológica extremamente rara, representando um grande problema cirúrgico. Realmente até 1960, quase todos os aneurismas de artérias viscerais eram detectados como rupturas fatais ou achados ocasionais em necrópsias. Neste artigo, os autores descrevem um caso de aneurismas múltiplos da artéria pancreatoduodenal que foi tratado através de ressecçäo cirúrgica no Serviço de Cirurgia Cardiovascular do Hospital da Polícia Militar do Rio de Janeiro (HPM-RJ), em junho de 1980, com um acompanhamento pós-operatório de 10 anos. Os autores, baseados neste caso e em uma revisäo extensa da literatura, concluem que, apesar do progresso nas técnicas radiológicas, o diagnóstico desta condiçäo patológica é comumente ocasional e deve ser tratado, quando possível, através de ressecçäo cirúrgica


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Aneurisma/diagnóstico , Aorta Abdominal/patologia , Artérias/lesões , Brasil
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...